真人游戏平台是一家集真人游戏平台,真人游戏平台,真人游戏平台于一体的综合性娱乐公司,为玩家提供全方位的游戏体验,诚邀您的体验。

  • <th id="7q9d3"></th>
    1. <code id="7q9d3"></code>
      1. <object id="7q9d3"></object>

        <code id="7q9d3"></code>
        Thermal Shock Test Chamber Manufacturer ,Vibration Shaker,Xenon Chamber , High Low Temperature Chamber Factory
        Hot search: High low Temperature Cycle Test Chamber UV Climate Resistant Aging Test Chamber Temperature Humidity Vibration Combined Test System HAST Impact Test Vibration Tester Temperature Humidity Test Chamber Thermal Shock Test Chamber
        PCT Aging testing chamber
        Xenon aging test chamber
        Temperature Humidity test chamber
        Temperature Humidity Vibration combined test system

        Customized Thermal Shock Test Chamber

        Customized Thermal Shock Test Chamber

          Customized Thermal Shock Test Chamber



          Customized Thermal Shock Test Chamber is used to test the capability of material structure or composite materials to withstand the continuous environmental changes between extremely high temperature and low temperature during a short period, and therefore understand the chemical changes or physical damages caused by expansion from heat and contraction from cold in the shortest possible time.


          Technical Parameters:

          Model

           TS-49(A~C)

          TS-80(A~C)

          TS-150(A~C)

          TS-252(A~C)

          TS-450(A~C)

          TS-900(A~C)

          Internal Dimension WxHxD (mm)

          400x350x350

          500x400x400

          600x500x500

          700x600x600

          800x750x750

          1000x900x900

          External Dimension WxHxD (mm)

          1400x1800x1400

          1550x1950x1550

          1600x2000x1700

          1700x2100x1750

          1800x2200x1900

          2100x2400x2200

          Temperature Range of Testing zone

          Type A:-40 ℃~+150℃ ( 200℃ is Optional)

          Type B:-55℃ ~+150℃ ( 200℃ is Optional )

          Type C:-65℃ ~+150℃ ( 200℃ is Optional)

          High temperature Range of Testing zone: +60oC~+150oC ( 200oC is Optional);

          Low Temperature Range of Testing Zone: -10oC~-40oC / -55oC / -65oC

          Exposure Time of High/Low Temperature

          Exposure Time of High Temperature: +60℃ ~ +150℃ (200℃ is Optional) 30Mins

          Exposure Time of Low Temperature : -10℃~Type A:-40℃ / Type B -55℃ / Type C -65℃ 30Mins

          Temperature of Heat-Storing Slot / Heating Time

          RT~200℃/About  45mins

          Temperature of Cool-storing Slot / Cooling Time

          RT~-75℃/ About 100mins

          Temperature Recovery Time / Conversion Time

          ≤5min/≤5sec  

          Control Accuracy / Distribution Uniformity

          ±0.5℃/±2℃

          Internal and External Material

          Material of the inner box is SUS 304# stainless steel,of the outer box is stainless steel or see cold-rolled steel with paint coated.

          Insulation Material

          High temperature resistant , high density , formate chlorine , ethyl acetum foam insulation materials

          Mechanics

          P.I.D+S.S.R+ Micro-computer balanced temperature control system

          Cooling System

          Semi-hermetic double-stage compressor(water-cooled type) /Hermetic double-stage compressor (air-cooled type)

          Security Protection Devices

          Non-fuse breaker, high and low pressure protective switch of the compressor , refrigerator high-pressure protective switch , failure warning system, electronic alarm

          Accessories

          viewing window(special order)

          Compressor

          French 'Tecumseh' Brand, Germany Bizer Brand

          Power

          AC220V 1 phase 3 lines ,50/60HZ, AC380V 3 phase 5 lines ,50/60HZ

          Weight (Approx)

          450 Kg

          600 Kg

          750 Kg

          900 Kg

          1300 Kg

          1500 Kg




          Features: 
          1.It is divided into three zones: high temperature zone, low temperature zone, and testing  zone. The test sample is in static mode.
          2.Using touch-control graph control as operation interface, easy to operate.
          3.Applying wind route conversation to the shock method to distribute temperature to the testing zone for cold and thermal shock measurement.
          4.For high temperature shock or low temperature shock, max. time is up to 999H, and max. circulation cycles are 9999 times.
          5.The system can be used for automatic Circulation Shock or manual selective shock.
          6.Adopt binary cooling system, with quick cooling effect. Cooling method is water cooling.
          7.Can entering normal temperature. RS-232 and RS-485 communication.


          Saftey device:
          1 Cooling System: Compressor heat loading or cold over loading warming
          2 Testing room: Testing room and Humidifier temperature over loading warming.  
          3 Others: Leakage protection. Heating, dry protection. Overload, short circuit protection.Power protection.

          Testing Specific:
          GB/T 2431.1-2001  Testing A: Low temperature testing method
          GB/T 2431.2-2001  Testing B: High temperature testing method
          GJB 150.3-1986: High temperature
          GJB 150.4-1986: Low temperature
          IEC68-2-1 Test A: Cold
          IEC68-2-2 Test A: Dry
          GB 11158 High and low temperature test term
          GB/T 2423.2  << Electrolic products basic environmental test: B: high temperature method>>